Starter of condition based maintenance by trending measurement in PC software
Starter of condition based maintenance by trending measurement in PC software
Starter of condition based maintenance by trending measurement in PC software
Vibration transducer | Accelerometer | Standard nom 100 mV/g | (Selectable sensitivity in the instrument) 0,1 - 99999 mV/g |
Input amplitude range | Vibration | Max 50 g RMS | With other sensor up to 500 g |
Bearing condition | Max 30 gBC | ||
Dynamic range | 80 dB (159 Hz with auto ranging) | ||
Frequency range | Vibration | 2 - 400 Hz 10 - 1000 Hz 6 - 1600 Hz 11 - 3200 Hz | User selectable |
Bearing condition | 0,5 to 16 kHz | ||
Vibration units | g-value, m/s2, mm/s, in/s, µm, mils | User selectable | |
Amplitude presentation | RMS, Peak, Peak-Peak | User selectable | |
Analysis | Five highest peaks can be displayed | VMI Trend View Software included for PC | |
Frequency range of peak de- tection | Frequency range | Same as ”frequency range”, except for 11-3200 Hz range, where peak detection ends at 2000 Hz | |
2 - 400 Hz | |||
6 - 1600 Hz | |||
11 - 2000 Hz | |||
10 - 1000 Hz | |||
Storage capacity | 100 measurements can be stored | ||
Three-point balancing | 10 balancing results can be stored | ||
Communication interface | USB 2.0 | ||
Sound frequency Filter enabled | 60 Hz - 10 kHz | +26 dB to -4.1 dB | |
500 Hz - 10 kHz | +26 dB to -4.1 dB | ||
Temperature sensor Range | Built-in infrared sensor | Temp. Sensor measures down to -20°C but the instru- ment ambient temp. must be 0°C or higher | |
-20 to +120°C | |||
Accuracy | Vibration | ± 3 % | Full scale is 50 g for acceleration other units are frequ- ency dependent |
Bearing condition | ± 5 % | Over 0.5 gBC | |
Frequency/RPM | ± 0,2 % | ||
Temperature | Emissivity factor must be set in accordance with the target surface | ||
Battery | Rechrageable Lithium | 2300 mA/h, max 60°C | Capacity of the batteries can vary depending on hardware revision. Max 2300 mA/h. (Storage temp. -20 to max 60°C) |
Operating time | 1 week normal use | Operating time depends on backlight, volume level and batteries used. Backlight adds 40mA and the sound volume up to 150 mA. Charging time is approx 6-12 hours | |
External charger | 5,0 V regulated @ 2000 mA | ||
LCD display | B&W 64 x 120 pixels with background light | Operating temp. min 0°C to max 50°C, storage temp. max 72°C | |
Enclosure protection | IP65 | ||
Operating temp. range | 0 to 50°C | The restriction concerns the display | |
Weight | 415 gram | Instrument, including battery and transducer | |
Size (L x W x H) | 165 mm x 80mm x 50mm | ||
OBS. If changing to another accelerometer, the sensitivity (mV/g) have to be changed. This is done in the menu under ”Transducer”. |